$2,761.65
Add to Cart
OHAUS Adventurer® Analytical Balance AX124/E, 120g x .1mg (30100601) Extl Cal
OHAUS Adventurer® Analytical Balance AX124/E, 120g x .1mg (30100601) External Cal Only
Intelligent Performance No Matter How Difficult the Task!
Fast stabilization and reliable operation are enhanced by the AutoCAL option to ensure solid weighing performance and accurate, repeatable results for standard laboratory applications.
The wide viewing angle color touchscreen provides access to all of Adventurer's applications, while dual USB ports with GLP/GMP tracking capabilities assist in the monitoring and reporting of data.
The two piece, top-mounted draft shield doors reduce the footprint of the doors in the rear of the balance when open, and open wide on both sides in order to provide ample room to place samples.
Technical Details:
Maximum Capacity 120 g
Readability 0.1 mg
Pan Size (Ø_Diameter) 90.0 mm (3.5 in)
Internal Calibration Not Applicable
Draftshield Included
Minimum Weight (USP), Typical 0.2 g
Inuse cover Included
Display Full-Color 4.3 in Touchscreen WQVGA
Linearity ± 0.2 mg
Auxiliary Display Model Available as an Accessory
Repeatability (typical) 0.1 mg
Dimensions (Length) 354.0 mm (13.93 in)
Dimensions (Width) 230.0 mm (9.05 in)
Dimensions (Height) 340.0 mm (13.39 in)
Stabilization Time 3 s
Test Weight 100g, OIML E2 or ASTM CL 1
Working Environment 50°F 85°F, 80%RH, non-condensing
Working Environment 10°C 30°C, 80%RH, non-condensing
Net Weight 5.1 kg (11.3 lb)
Battery Life Not Applicable
Legal for Trade Not Applicable
Pan Construction Stainless Steel
Power AC Adapter (Included)
Tare Range To capacity by subtraction
Intelligent Performance No Matter How Difficult the Task!
Fast stabilization and reliable operation are enhanced by the AutoCAL option to ensure solid weighing performance and accurate, repeatable results for standard laboratory applications.
The wide viewing angle color touchscreen provides access to all of Adventurer's applications, while dual USB ports with GLP/GMP tracking capabilities assist in the monitoring and reporting of data.
The two piece, top-mounted draft shield doors reduce the footprint of the doors in the rear of the balance when open, and open wide on both sides in order to provide ample room to place samples.
Technical Details:
Maximum Capacity 120 g
Readability 0.1 mg
Pan Size (Ø_Diameter) 90.0 mm (3.5 in)
Internal Calibration Not Applicable
Draftshield Included
Minimum Weight (USP), Typical 0.2 g
Inuse cover Included
Display Full-Color 4.3 in Touchscreen WQVGA
Linearity ± 0.2 mg
Auxiliary Display Model Available as an Accessory
Repeatability (typical) 0.1 mg
Dimensions (Length) 354.0 mm (13.93 in)
Dimensions (Width) 230.0 mm (9.05 in)
Dimensions (Height) 340.0 mm (13.39 in)
Stabilization Time 3 s
Test Weight 100g, OIML E2 or ASTM CL 1
Working Environment 50°F 85°F, 80%RH, non-condensing
Working Environment 10°C 30°C, 80%RH, non-condensing
Net Weight 5.1 kg (11.3 lb)
Battery Life Not Applicable
Legal for Trade Not Applicable
Pan Construction Stainless Steel
Power AC Adapter (Included)
Tare Range To capacity by subtraction